Below details mentioned are event details listed on a per Category basis.
Severity Level |
Policy ID |
Description |
Cause |
Resolution |
9 |
HW.X1.1 |
HW.X1.1: System Hardware Fan Failing **$0** |
HW.X1.1: Alert when a Hardware Fan has failed |
HW.X1.1: This checks the Server System status in the idrac for failed fans. If the event persists, generate a TSR report or Support Assistant log on the Dell Server and contact Panzura Technical Support |
6 |
HW.X1.2 |
HW.X1.2: System Hardware Chassis Intrusion Detected |
HW.X1.2: Alert when the Hardware Chassis has been opened |
HW.X1.2: This checks the Server System event logs in the idrac for open chassis. If the event persists, generate a TSR report or Support Assistant log on the Dell Server and contact Panzura Technical Support |
10 |
HW.X1.3 |
HW.X1.3: System Hardware Power Supply Failing |
HW.X1.3: Alert when a Hardware Power Supply has failed |
HW.X1.3: If the event persists, check the Server System event logs in the iDRAC WebUI for Power Supply failures and contact Panzura Technical Support. |
6 |
HW.X1.4 |
HW.X1.4: System Hardware Inlet Temperature Near Critical at $0 |
HW.X1.4: Alert when the environmental temperature is approaching Vendor Critical |
HW.X1.4: If the event persists, check the Server System event logs for temperature messages and contact Panzura Technical Support. |
9 |
HW.X1.5 |
HW.X1.5: System Hardware Inlet Temperature Critical at $0 |
HW.X1.5: Alert when the environmental temperature is above Vendor Critical |
HW.X1.5: If the event persists, ensure that the Server Room has an active A/C and contact Panzura Technical Support. |
7 |
HW.X1.6 |
HW.X1.6: System Hardware **$0** reporting distress |
HW.X1.6: Alert when there are general Hardware Distress Indicators |
HW.X1.6: If the event persists, check the Server system event logs for hardware errors and contact Panzura Technical Support. |